Bulletin of the Seismological Society of America
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Bulletin of the Seismological Society of America; June 2008; v. 98; no. 3; p. 1495-1507; DOI: 10.1785/0120060263
© 2008 Seismological Society of America
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schaff, D. P.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

Semiempirical Statistics of Correlation-Detector Performance

David P. Schaff

Lamont-Doherty Earth Observatory, 61 Route 9W, Palisades, New York 10964 dschaff{at}LDEO.columbia.edu

Statistical analyses were conducted on the capability of correlation detectors for similar events. Semiempirical synthetic runs took a 50-sec window on an Lg wave recorded at 750-km distance filtered from 1 to 3 Hz and embedded it 300,000 times in real continuous background seismic noise. The noise was selected for 36 days spread throughout the year to capture diurnal and seasonal variations. No screening for random, unknown signals in the noise was performed. A correlation detector has a 50% probability of detection with 1.5 false alarms per day for a signal-to-noise ratio (SNR) of 0.32, which corresponds to a full magnitude unit reduction in detection threshold over a standard short-term average/long-term average (STA/LTA) technique. A scaled cross-correlation coefficient performs slightly better with one false alarm per day and has fewer false triggers on unknown, random signals. Summing the cross-correlation traces together for all three components enhances the detection signal similar to beamforming. A correlation detector summing the correlation traces for the three components together has a 96% probability of detection with zero false alarms in 36 days for an SNR of 0.32. The significant result of this study is that a correlation detector has more than an order of magnitude improvement in detection threshold for similar events with acceptably low false alarm rates to be used in practice.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Seismological Society of America.