Bulletin of the Seismological Society of America
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Bulletin of the Seismological Society of America; April 2003; v. 93; no. 2; p. 546-556; DOI: 10.1785/0120020107
© 2003 Seismological Society of America
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Crouse, C. B.
Right arrow Articles by Ramirez, J. C.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

Article

Soil-Structure Interaction and Site Response at the Jensen Filtration Plant during the 1994 Northridge, California, Mainshock and Aftershocks

C. B. Crouse and Juan Carlos Ramirez

URS Corporation
1501 4th Avenue, Suite 1400
Seattle, Washington 98101-1616
cb_crouse{at}urscorp.com
juan_carlos_ramirez{at}urscorp.com
(C.B.C., J.C.R.)

The effects of soil-structure interaction (SSI) and nonlinear site response (SR) on the Northridge mainshock and aftershock motions recorded at two buildings in the Jensen Filtration Plant were investigated. Forced vibration tests conducted on the small one-story generator building and the larger three-story administration building, both of which recorded the mainshock and two aftershock sequences, revealed a prominent mode of vibration at 6.2 Hz in the short (east–west) direction of the administration building. However, models of inertial SSI, calibrated to the vibrationtest data, demonstrated that this phenomenon was of secondary importance, even when adjusted for nonlinear behavior of the soil and structure. Nonlinear SR and kinematic SSI were identified as the main reasons for the differences observed in the three sets of building earthquake records, each with clearly distinct amplitude and duration characteristics. Unfortunately, the absence of free-field recordings at both buildings during the mainshock and first aftershock sequence prevented a clearer determination of the relative roles of these two phenomena. Fortunately, the installation of free-field instruments outside both buildings 4 yr later revealed the significance of both effects, albeit at extremely small motion amplitudes. This case history further emphasizes the need to carefully plan the siting of ground-motion instrumentation so that the interpretations of any recorded data are not obscured by the potential effects of SSI.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the Seismological Society of America.