Bulletin of the Seismological Society of America
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Bulletin of the Seismological Society of America; October 1996; v. 86; no. 5; p. 1608-1622
© 1996 Seismological Society of America
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hammer, J. K.
Right arrow Articles by Langston, C. A.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

Modeling the effect of San Andreas fault structure on receiver functions using elastic 3D finite difference

John K. Hammer and Charles A. Langston

Department of Geosciences The Pennsylvania State University, University Park, Pennsylvania 16802

Abstract

Teleseismic P-wave data collected at the San Andreas Observatory (SAO) seismic station show strong frequency-dependent, nonrectilinear particle motions consisting of off-azimuth horizontal displacements that are sometimes larger than the vertical displacements. The azimuthal dependence of the horizontal components amplitude is directly related to the symmetry of the fault zone. A 3D finite-difference program (Frankel and Vidale, 1992) is used to examine the response of the San Andreas fault-zone velocity structure to incident teleseismic P waves. Synthetic seismograms are formed using a 3D representation of an assumed 2D fault-zone structure. The fault-zone velocity model produces large-amplitude phases that contain combinations of refracted and internally reflected P-to-S converted phases, diffractions, and possible P-to-Rayleigh converted phases. The largest-amplitude phases observed in the data are nondispersive and have complicated particle motions confined to the vertical plane perpendicular to the fault zone. The data are fit best by synthetic receiver functions for field points similar to the location of SAO relative to the San Andreas fault zone. Since the velocity model used in the computations is nonunique, sensitivity studies were performed by modifying the structure. Synthetics match the timing and nature of the observed phases at SAO showing that assumption of plane-layered structure is invalid in the area of this station.




This article has been cited by other articles:


Home page
Bulletin of the Seismological Society of AmericaHome page
The Vertical Component P-Wave Receiver Function
Bulletin of the Seismological Society of America, December 1, 2001; 91(6): 1805 - 1819.



Home page
Bulletin of the Seismological Society of AmericaHome page
G. A. Abers
Array measurements of phases used in receiver-function calculations: Importance of scattering
Bulletin of the Seismological Society of America, February 1, 1998; 88(1): 313 - 318.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the Seismological Society of America.