Bulletin of the Seismological Society of America
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Bulletin of the Seismological Society of America; October 1994; v. 84; no. 5; p. 1580-1592
© 1994 Seismological Society of America
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fels, J.-F.
Right arrow Articles by Berger, J.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

Parametric analysis and calibration of the STS-1 seismometer of the IRIS/IDA Seismographic Network

Jean-Francois Fels and Jon Berger

Institute of Geophysics and Planetary Physics Scripps Institution of Oceanography University of California-San Diego, San Diego, California 92037

Abstract

We have estimated the observed system response of STS-1 sensors installed at stations of the IRIS/IDA Seismographic Network using cross-spectral analysis of random binary calibration signals. Systematic deviations of up to 1% in amplitude and 1° in phase between the measured and the manufacturers "nominal" responses are observed in the range 0.2 to 100 mHz and up to 12% in amplitude and 5° in phase for frequencies above 5 Hz. A parametric analysis of the STS-1 seismometer is developed that leads to a more complete pole and zero model of the sensor, accounting accurately both for small changes in individual instrument parameters and for the effects of an incomplete compensation of the mechanical response by the feedback circuit. This model is then used to fit the observed responses with a precision of 0.2% for the amplitude and 0.1° for the phase over the entire useful bandwidth of the instrument.




This article has been cited by other articles:


Home page
Seismological  Research LettersHome page
P. Davis and J. Berger
Calibration of the Global Seismographic Network Using Tides
Seismological Research Letters, July 1, 2007; 78(4): 454 - 459.
[Full Text] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
R. Sleeman, A. van Wettum, and J. Trampert
Three-Channel Correlation Analysis: A New Technique to Measure Instrumental Noise of Digitizers and Seismic Sensors
Bulletin of the Seismological Society of America, February 1, 2006; 96(1): 258 - 271.
[Abstract] [Full Text] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
E. Canuteson, M. Zumberge, and J. Hanson
An absolute method of vertical seismometer calibration by reference to a falling mass with application to the measurement of the gain
Bulletin of the Seismological Society of America, April 1, 1997; 87(2): 484 - 493.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the Seismological Society of America.