Volumetric strain meters (Sacks-Evertson design) are installed at 15 sites along the San Andreas fault system, to monitor long-term strain changes for earthquake prediction. Deployment of portable broadband, high-resolution digital recorders (GEOS) at several of the sites extends the detection band for volumetric strain to periods shorter than 5 x 102 sec and permits the simultaneous observation of seismic radiation fields using conventional short-period pendulum seismometers. Simultaneous observations establish that the strain detection bandwidth extends from periods greater than 107 seconds to periods near 5 x 102 sec with a dynamic range exceeding 140 dB. Measurements of earth-strain noise for the period band, 107 to 102 sec, show that ground noise, not instrument noise, currently limits the measurement of strain over a bandwidth of more than eight orders of magnitude in period. Comparison of the short-period portion of earth-strain, noise spectra (20 to 5 x 102 sec) with average spectra determined from pendulum seismometers, suggest that observed noise is predominantly dilatational energy. Recordings of local and regional earthquakes indicate that dilatometers respond to P energy but not direct shear energy and that straingrams can be used to resolve superimposed reflected P and S waves for inference of wave characteristics not permitted by either sensor alone. Simultaneous measurements of incident P- and S-wave amplitudes are used to introduce a technique for single-station estimates of wave field inhomogeneity, free-surface reflection coefficients and local material P velocity. Estimates of these parameters derived for the North Palm Springs earthquake (Mw 5.9) respectively for an incident P wave of 29° are 85°, 1.71, 2.9 km/sec, and for an incident S wave of 17° are 79°, 0.85, 2.9 km/sec. The empirical estimates of reflection coefficients are consistent with model estimates derived using an anelastic half-space model with incident inhomogeneous wave fields.
This article has been cited by other articles:
![]() |
D. C. Agnew and K. Hodgkinson Designing Compact Causal Digital Filters for Low-Frequency Strainmeter Data Bulletin of the Seismological Society of America, February 1, 2007; 97(1B): 91 - 99. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. S. Johnston, R. D. Borcherdt, A. T. Linde, and M. T. Gladwin Continuous Borehole Strain and Pore Pressure in the Near Field of the 28 September 2004 M 6.0 Parkfield, California, Earthquake: Implications for Nucleation, Fault Response, Earthquake Prediction, and Tremor Bulletin of the Seismological Society of America, September 1, 2006; 96(4B): S56 - S72. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. D. Borcherdt, M. J. S. Johnston, G. Glassmoyer, and C. Dietel Recordings of the 2004 Parkfield Earthquake on the General Earthquake Observation System Array: Implications for Earthquake Precursors, Fault Rupture, and Coseismic Strain Changes Bulletin of the Seismological Society of America, September 1, 2006; 96(4B): S73 - S89. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Gomberg and D. Agnew The accuracy of seismic estimates of dynamic strains: An evaluation using strainmeter and seismometer data from Pinon Flat observatory, California Bulletin of the Seismological Society of America, February 1, 1996; 86(1A): 212 - 220. [Abstract] [PDF] |
||||
![]() |
R. J. Mueller, M.-y. Lee, M. J. S. Johnston, R. D. Borcherdt, G. Glassmoyer, and S. Silverman Near real-time monitoring of seismic events and status of portable digital recorders using satellite telemetry Bulletin of the Seismological Society of America, April 1, 1995; 85(2): 640 - 645. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |