Bulletin of the Seismological Society of America
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Bulletin of the Seismological Society of America; February 1974; v. 64; no. 1; p. 103-113
© 1974 Seismological Society of America
This Article
Right arrow Full Text (PDF)
Right arrow References
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by KANASEWICH, E. R.
Right arrow Articles by RAMSDELL, L.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

Gain-ranging analog or digital seismic system

E. R. KANASEWICH, W. P. SIEWERT, M. D. BURKE, C. H. MCCLOUGHAN and L. RAMSDELL

SEISMOLOGY DIVISION INSTITUTE OF EARTH AND PLANETARY PHYSICS DEPARTMENT OF PHYSICS, UNIVERSITY OF ALBERTA, EDMONTON, ALBERTA T6G 2E1 Canada

Abstract

A wide-band, gain-ranging amplifier is described that may be used for recording data with a dynamic range of 60 db in each of three different levels, 12 db apart, so that we achieve an "effective" dynamic ±160-v analog or 84-db digital, within a normal ±10-v analog system. As described, the ranging circuit reduces the gain of the amplifier by a factor of either 4 or 16 whenever the output signal approaches the maximum for the system. The wide-band response is achieved with low-noise operational amplifiers and second-order active filters. Signals with periods greater than 30 sec are amplified by 100 db and those with periods shorter than 1 sec are amplified by 70 db. The system works well in extending the useful output range of a Willmore Mark II seismometer with a natural period of 1.5 sec to over 40 sec under normal field operating conditions. When analog recording, the gain-range switching occurs when the input signal reaches ±8.1-v; when digital recording, the level is ±9.375 v. The period in a divide-by-4- or 16-state is preset by the experimentalist. The gain level is recorded on an extra channel which is also used to record absolute time.




This article has been cited by other articles:


Home page
Bulletin of the Seismological Society of AmericaHome page
R. G. DANIEL
An intermediate-period field system using a short-period seismometer
Bulletin of the Seismological Society of America, October 1, 1979; 69(5): 1623 - 1626.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1974 by the Seismological Society of America.