Bulletin of the Seismological Society of America
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Bulletin of the Seismological Society of America; July 1949; v. 39; no. 3; p. 205-218
© 1949 Seismological Society of America
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by CHAKRABARTY, S. K.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

Response characteristics of electromagnetic seismographs and their dependence on the instrumental constants

S. K. CHAKRABARTY

BENGAL ENGINEERING COLLEGE,, HOWRAH, India

Abstract

The equation of motion of the seismometer and the galvanometer in an electromagnetic seismograph has been derived in the most general form taking into consideration all the forces acting on the system except that produced by hysteresis. A general solution has been derived assuming that the earth or the seismometer frame is subjected to a sustained simple harmonic motion, and expressions for both the transient and the steady term in the solution have been given. The results for the particular case when the seismograph satisfies the Galitzin conditions can easily be deduced from the results given in the present paper. The results can now be used to study the response characteristics of all electromagnetic seismographs, whether they satisfy the Galitzin conditions or not, and will thus give an accurate theoretical picture of the response also of seismographs used for the study of "local earthquakes" and "microseisms" which do not in general obey the Galitzin conditions. The results obtained can also be used to get analytically the response of the seismographs for different types of earth motion from the very beginning, and not only after the transient term has disappeared.

The theory of the response to simple tests used to determine the dynamic magnification of any seismograph and also to determine and check regularly the instrumental constants of the seismographs has been worked out. The results obtained can also be used for ascertaining the proper values of the instrumental constants suitable for the various purposes for which the seismographs are to be used.




This article has been cited by other articles:


Home page
Bulletin of the Seismological Society of AmericaHome page
W. MITRONOVAS and E. WIELANDT
High-precision phase calibration of long-period electromagnetic seismographs
Bulletin of the Seismological Society of America, April 1, 1975; 65(2): 411 - 424.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
H. JAROSCH and A. R. CURTIS
A note on the calibration of the electromagnetic seismograph
Bulletin of the Seismological Society of America, June 1, 1973; 63(3): 1145 - 1155.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
S. DOPP
Application of communication network theory to the electromagnetic seismograph
Bulletin of the Seismological Society of America, October 1, 1964; 54(5A): 1479 - 1489.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
F. E. ROMBERG
Analytical expressions for transients in seismometer-galvanometer systems
Bulletin of the Seismological Society of America, April 1, 1963; 53(3): 563 - 576.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
A. F. ESPINOSA, G. H. SUTTON, and H. J. MILLER
A transient technique for seismograph calibration
Bulletin of the Seismological Society of America, October 1, 1962; 52(4): 767 - 779.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
S. K. CHAKRABARTY and A. N. TANDON
Calibration of electromagnetic seismographs satisfying galitzin conditions
Bulletin of the Seismological Society of America, January 1, 1961; 51(1): 111 - 125.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
R. E. INGRAM
An integral solution of the electromagnetic seismograph equation
Bulletin of the Seismological Society of America, July 1, 1960; 50(3): 461 - 465.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
P. W. POMEROY and G. H. SUTTON
The use of galvanometers as band-rejection filters in electromagnetic seismographs
Bulletin of the Seismological Society of America, January 1, 1960; 50(1): 135 - 151.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
S. K. CHAKRABARTY and D. SARKER
Microseisms associated with norwesters
Bulletin of the Seismological Society of America, April 1, 1958; 48(2): 181 - 189.
[Abstract] [PDF]


Home page
Bulletin of the Seismological Society of AmericaHome page
J. P. EATON
Theory of the electromagnetic seismograph
Bulletin of the Seismological Society of America, January 1, 1957; 47(1): 37 - 75.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1949 by the Seismological Society of America.